Indoor Air Quality Concepts, Technologies and Solutions for a Brighter, Post-Pandemic Future

Next Course Date: 17 May 2022

Time: 9am - 5pm

Mode of delivery: Face-to-face


Course Summary

Indoor Air Quality (IAQ) is one of the many factors that determine building functionality and economics. Good IAQ plays a vital role in creating a healthy and productive workplace. During this one-day course, the trainer will discuss the issues and problems of poor IAQ and how the problems can be mitigated through effective HVAC system design and practices and deployment of advanced air cleaning technologies.


Rates (inclusive of GST)

Standard: S$480

SEAS Member: S$418

SCEM: S$430

Certificate

All participants will receive a Certificate of Attendance from SEAS upon completion.

SCEM Participants will be awarded with 7 PDU Points



Course Objective

The participants of this course will acquire the following skills:

  • Understanding of various factors which impact IAQ
  • Fundamental knowledge of building related illnesses, their causes and effects
  • Adoption of a holistic integrated approach in designing of building systems to improve occupant health and well-being
  • Development of creative HVAC system design skills to maximize IAQ and energy performance

Cleanroom Energy Efficiency

Next Course Dates: 01 & 02 August 2021

Time: 9am - 5pm

Mode of delivery: Online


Course Summary

The high technology sectors in both industrial and commercial areas in Singapore house several cleanrooms, these have become essential in the production and manufacturing process.


The essential concepts and understanding of cleanroom technology is gaining importance as professionals are tasked to maintain and operate these cleanrooms. Within this 2 days' workshop, examples of cleanroom applications include the manufacture of integrated circuits, electronic components, precision mechanical assemblies, info-communication technology, medical field, pharmaceuticals and bio-chemicals industry and others. This course aims to help energy managers optimise the energy usage for a cleanroom.


Rates (inclusive of GST)

Standard: S$780

SEAS Member: S$650 

SCEM: S$720

Certificate

All participants will receive a Certificate of Attendance from SEAS upon completion.

SCEM Participants will be awarded with 14 PDU Points


Course Objective

Upon completion of this course, the participants should be able to develop good understanding of:


  • Cleanroom Basics
  • Applications and Classification of cleanrooms
  • Basic design of cleanrooms within different sectors and industries
  • Air conditioning, air change rates and mechanical ventilation requirement for cleanrooms
  • Standards for the cleanrooms design and operation
  • Application of demand ventilation control
  • Cost benefit analysis of energy retrofit projects and projection

Green Data Centre Design

Next Course Dates: 15 & 16 August 2022

Time: 9am - 5pm

Mode of delivery: Face-to-face


Course Summary

Energy expenditures account for the vast majority of the operating costs during a data centre lifetime, and this fact is becoming critical in order to ensure business profitability.


This 2-day green data centre design course will equip participants with in-depth knowledge of SS564 and Green Mark for New and Existing Data Centre. The 2-day course will also include design best practices and case studies to empower participants with knowledge and ideas to green their data centres: Data Centre (DC) Overview and Trends, SS564, Green Mark for DC Overview, GM for New & Existing DC, DC Air Conditioning System Design, DC Electrical System Design, DC Operations, DC Performance Monitoring.


Rates (inclusive of GST)

Standard: S$858

SEAS Member: S$715 

SCEM: S$792

Certificate

All participants will receive a Certificate of Attendance from SEAS upon completion.

SCEM Participants will be awarded with 14 PDU Points



Course Objective

At the end of the course, the participants will be able to:


  • Understand Green data centre standards such as Green Mark for new and existing data centres
  • Apply the best practices in chiller plant, computer room air-conditioning, lighting and uninterruptible power system design
  • Optimise, monitor and maintain the data centres at peak energy efficiency
Menu